OVERVIEW
Parker Industrial Boiler - Model 70, National Board & Manufacturer's Serial Number 44253, Year Built 1994. Professional-grade natural gas-fired steam boiler featuring 2,940,000 BTU/HR input capacity with 125 PSI maximum allowable working pressure, 349 square feet heating surface, and 70 boiler horsepower rating. Complete packaged system with burner assembly, combustion controls, feedwater controls, and all safety trim. Built to ASME standards with 125 PSI safety valve and trim maximum pressure rating. Gas supply requirement: 4" W.C. at burner. Asset ID: BL-01. Manufactured by Parker Boiler Co., Los Angeles, CA. Ideal for commercial buildings, light industrial facilities, institutional applications, healthcare facilities, food service operations, or any operation requiring reliable steam generation with proven Parker quality and compact design.
EQUIPMENT SPECIFICATIONS
Boiler Model Information:
- Manufacturer: Parker Boiler Co.
- Location: 5930 Bandini Blvd., Los Angeles, CA 90040
- Product Line: Parker Industrial Boiler
- Model Number: 70
- National Board & MFG's Serial Number: 44253
- Year Built: 1994
- Boiler Horsepower: 70 HP
- Configuration: Steam boiler
- Type: Natural gas-fired
- Asset ID: BL-01
Performance Ratings:
- Boiler Horsepower: 70 HP (Model or Horsepower)
- BTU Input: 2,940,000 BTU
- Heating Surface: 349 sq. ft.
- Maximum Allowable Working Pressure: 125 PSI
- Safety Valve and Trim Maximum Pressure: 125 PSI
- Fuel Type: Natural Gas
- Gas Requirement: 4" W.C. required at burner
Electrical Specifications:
- (Specifications per equipment installation)
Control Systems:
- Burner control system
- Feedwater level controls
- Low water cutoff
- Operating pressure controls
- Safety interlocks
- Pressure gauge mounted
Safety Systems:
- Safety valve rated 125 PSI maximum
- Low water cutoff protection
- Pressure relief protection
- Safety trim included
- Multiple safety interlocks
KEY FEATURES & BENEFITS
Parker Boiler Quality:
- Premium USA boiler manufacturer
- 1994 manufacture
- Los Angeles, California facility
- Parker Industrial series
- 70 HP capacity
- ASME certified construction
- Heavy-duty commercial construction
- Professional installation quality
High-Efficiency Performance:
- 70 HP boiler capacity
- 2,940,000 BTU/HR input
- 349 sq. ft. heating surface
- 125 PSI maximum working pressure
- Natural gas fuel efficiency
- Reliable steam generation
- Continuous duty rated
- Proven performance
Complete Package System:
- Factory assembled boiler
- Burner system installed
- Combustion controls included
- Feedwater control system
- All safety devices and trim
- Pressure gauge included
- Ready for field installation
- Professional engineering
Safety & Compliance:
- 125 PSI ASME design pressure
- Safety valve rated 125 PSI
- Low water cutoff protection
- Multiple safety interlocks
- Code-compliant installation
- Professional engineering
- All required safety trim
- Industrial safety standards
SYSTEM COMPONENTS
Main Boiler:
- Parker Model 70
- Serial Number 44253
- Year 1994 manufacture
- 70 HP capacity
- 349 sq. ft. heating surface
- 125 PSI MAWP
- Complete with all trim
- All safety controls included
Burner System:
- Natural gas burner
- 2,940,000 BTU input
- Gas train components
- 4" W.C. gas requirement at burner
- Burner management system
- Flame safeguard controls
- Safety shut-off valves
- Ignition system
Control Systems:
- Burner management controls
- Feedwater level controls
- Low water cutoff
- Operating pressure controls
- Safety interlocks
- Monitoring systems
- Pressure gauge
Feedwater Controls:
- Feedwater control system
- Level control components
- Low water protection
- Automatic operation
Safety & Instrumentation:
- Safety relief valve (125 PSI rated)
- Pressure gauge
- Temperature sensors
- Safety interlocks
- Emergency shutdown capability
- Pressure relief protection
- ASME certified components
SPECIFICATIONS SUMMARY
Boiler:
- Manufacturer: Parker Boiler Co.
- Location: Los Angeles, CA
- Model: 70
- Serial: 44253
- Year: 1994
- Capacity: 70 HP
- BTU Input: 2,940,000
- Heating Surface: 349 sq. ft.
- Max Pressure: 125 PSI
- Safety Valve: 125 PSI max
- Type: Steam boiler
- Origin: USA
Fuel:
- Type: Natural Gas
- Gas Requirement: 4" W.C. at burner
Physical:
- Configuration: Package boiler
- Construction: ASME certified
- Mounting: Floor-mounted
- Asset ID: BL-01
ADDITIONAL INFORMATION
- Condition: Used - 1994 Manufacture
- Manufacturer: Parker Boiler Co.
- Product Line: Parker Industrial Boiler
- Model: 70
- National Board & MFG's Serial Number: 44253
- Year Built: 1994
- Boiler Horsepower: 70 HP
- BTU Input: 2,940,000 BTU
- Heating Surface: 349 square feet
- Maximum Allowable Working Pressure: 125 PSI
- Safety Valve and Trim Maximum Pressure: 125 PSI
Fuel Type: Natural Gas
- Gas Requirement: 4" W.C. (Water Column) required at burner
Asset Identification: BL-01
Safety Features:
- 125 PSI rated safety valve
- Low water cutoff protection
- Safety interlocks
- Emergency shutdown capability
- Pressure relief protection
- All safety trim included
Installation Requirements:
- Must be installed on non-combustible floor
- All instructions must be followed exactly
- Proper clearances required per manufacturer specifications
Features:
- Parker Industrial Boiler Model 70
- 1994 year of manufacture
- 70 boiler horsepower rating
- 2,940,000 BTU/HR input capacity
- 349 square feet heating surface
- 125 PSI maximum allowable working pressure
- Natural gas-fired operation
- 4" W.C. gas pressure required at burner
- Complete packaged system with burner
- Combustion control system included
- Feedwater control system
- All safety devices and trim included
- ASME certified construction
- 125 PSI rated safety valve and trim
- Low water cutoff protection
- Safety interlocks
- Pressure gauge mounted
- Ready for field installation
- Professional-grade commercial construction
- Proven Parker quality and reliability
Location: Ohio

Get Your Price from C3 Surplus LLC!

Buyers Who Viewed This Listing Also Viewed …

Parker Boiler #T3600, Direct-Fired Hot Water Boiler, 240°F, 125 psig, nat gas, 115 Volts, modulating ctrl, 2024 (2 available)

Seller: Aaron Equipment Co
Location: Schaumburg, IL
Model: T3600
unused- parker industrial boiler model t3600, direct-fired hot water boiler. built 2024. heating surface 666 square feet. rated 3,600 mbh input, 2,880 mbh output. csd-1, asme, 115v/1ph. modulating, 125 psig mawp, natural gas fired. operating with max temperature up to 240 degrees f. recommended 20 to 40 degree delta ...more

250 HP Hurst #500-Series, Scotch Marine firetube Boiler, wet-back design, 125 PSI, 2013

Seller: C3 Surplus LLC
Location: Miami, FL
Mfr: Hurst
Model: 500-SERIES
Year: 2013
Overview, This used 250 HP Hurst 500 Series Scotch Marine Boiler, manufactured in 2013, offers high-efficiency hot water heating for demanding commercial and industrial applications. Designed for reliable performance, this unit operates at a maximum pressure of 125 PSI and s a three-pass firetube configuration to ...more

3 HP American Bending oil boiler, 174 sq.ft.surf, coil 125 psi @ 650°F, Maxon burner sz.EB2,3 HP blower, gas fired, #40477

Seller: Federal Equipment Company
Location: Cleveland, OH
Mfr: American
Model: 40477
Used American Bending Co Oil Boiler, 174 Sq Ft Surface Area, Coil Rated 125 Psi At 650 F With Maxon Burner, Size Eb2, Serial# 758604, New 2002 With 3 Hp, 230/460 Volt Blower, Gas Fired, Horizontal Orientation, Coil Serial# 8741352B, built 1987.

Share