Advanced Search
Surplus Record


BOILERS, WATERTUBE

3500 PPH Clayton steam generator, 15-500 psig, Nat.gas, 100HP, removed from service, 2007

Request a Quote
Share
3500 PPH Clayton steam generator, 15-500 psig, Nat.gas, 100HP, removed from service, 2007
Clayton Boiler, 100 hp, April 1987
High Pressure Type Up To 500 psig
Model E-100
S/N: 22874
Specs:
The following information was provided from the manual:
Boiler HP: 100
Net Heat Output: 3,347,500 btu/hr
Output (at 100 psig): 2,882
Design Pressure: 15-500 psig
Operating Pressure: 14-450 psig
Thermal Efficiency (gas): 80%
Gas Input: 4,184,375 btu/hr
Gas Supply Pressure (w/ regulator): .5-5.0 psig
Gas Supply Pressure (w/o regulator): 8 WCI
Water Supply: 530 gph
Net Positive Head for Feedwater: 10 feet
Heating Surface: 198 SQ. FT.
Coil Water Content: 16.5 gal
Combustion Volume: 9 cu ft.
Electric Motor: 7.5 hp
Overall Dimensions: 14 x 8 x 12, approx 4,000 lbs
These systems were operated in a facility that no longer had an application and were removed in 2007.
PRELIMINARY SPECIFICATIONS SUBJECT TO VERIFICATION