Steam-Turbine Driven Chicago Blowers Size 4100 S/N 164566-HDX-1 Unit #1, S/N 164566-HDX-2 Unit#2 Design Capacity: 15,142CFM At 27.2(Inches WG) Static Pressure 0.049 Lbs/Cubic Foot At 220˚F With 68.9% Static Efficiency Outlet Velocity: 5883 Feet/Minute R.H. Fan CCW Rotation From Coupling Unit #1, CW Rotation From Coupling Unit #2 IDF255-2 45-15/16 Effective Diameter Fan, Design 2312B 11 Vane Fan Wheel, Inconel ASTM B443 Construction Suction Flange: 26-13/16O.D. By 21-13/16I.D. 16 5/8 OD Holes On 24-9/16 B.C. Discharge Flange: 27-1/2 By 18 O.D. 11-3/4 By 21-1/4 I.D. Turbine Mfg. Coppus Engineering Manual # 90T5049 Unit #1, 90T5050 Unit #2 Fiberglass Insulation 95HP 3500RPM 9 No. 6 Nozzles 180psi At 380˚F And 10psi Exhaust 9000RPM Critical Speed 3675 Max Continuous RPM 900RPM Minimum 4060RPM Trip Type RLA20L RH Exhaust Unit #1, LH Exhaust Unit #2 Fisher Controls 2 Steam Inlet On 6.5 OD Flange, ANSI B16.1 250#, 8 Bolt Hole 6 Exhaust On 11-1/4 OD Flange, ANSI B16.1 125#, 8 Bolt Hole Fisher Actuator Type 513R Size 20, 50psig Air Supply Dynalco SPD 100 Tachometer To Magnetic Pickup Lufkin Reducer Model S64CH S/N 7399 1.975:1 Reduction 3500RPM In S.F. 3 285HP Rating Order # 830631 2 Gallon Reservoir Tuthill Lube Oil Pump BASCO Lube Oil Cooler Size 03014 1NPT Inlet & Outlet Overall Maximum Dimensions: 73 Wide By 70 High By 112 Long Weight Approximately 4600# 2 Unused |

| Merchant Vessel Machy Replace PO Box 716 Wilmington, CA 90748-0716 |
| Contact: V. Richardson Tel: 310-830-0461 Fax: 310-830-8355 |
Email: bzanettei@aol.com In the Surplus Record since 1976 |
View our Machinery/Equip. Listings |
Blowers & Fans Boilers Compressors Air & Gas Generators |
Heat Exchangers Pumps Turbines Valves |