TURBINES, STEAM w/out GENERATOR (Also See Generators, A.C., Steam (Turbine) Driven)

710 HP Turbodyne Fr. 286WVK, 830 psi, 930 deg.FTT w/gear, 6772/870 RPM, new

Request a Quote
Share
710 HP Turbodyne Fr. 286WVK, 830 psi, 930 deg.FTT w/gear, 6772/870 RPM, new
710 HP Turbodyne Steam Turbine

Application: Ballast Pump Driver
Serial Number: 33288
Turbine Frame: 286S WVK
Gear Frame: H-5 18X10-1/2
Stage: 1 Curtis
Rating: 710HP at 6772/870RPM
Rotation: CCW, Viewed from Governor
Steam Conditions: 830psig / 930˚FTT / 18”Hg Absolute Exhaust
Casing: Cast Steel
3” Steam Inlet / 900#ASA Flange
12” Exhaust / 150# ASA Flange
4257RPM 1st Critical Speed
Steam Rate: 12.4#/Hour
Steam Flow: 19,080#/Hour Maximum
Special Conditions: 1200BHP at 1100psig / 950˚F / 5psig Exhaust
38GPM Seawater required for Lube Oil Cooling
Governor: Requires Woodward Direct Acting PG-PL Governor
Overspeed Trip Setting: 7449RPM
Gimpel Throttle Trip Valve Dwg: S-399
Dimensions: 78.38” Wide By 100.19” Long By 61.87” High
Approximate Weight: 15,200#
1 Unused